| 醫(yī)用臥式方形脈動真空壓力蒸汽滅菌器 品牌:雙哈,哈哈 型號:YX 0.6WM脈動真空(Pulsating Vacuum) 產(chǎn)地:上海 產(chǎn)品注冊號:滬械注準20172570122 用途: 醫(yī)用 招商狀態(tài):招商中 招商區(qū)域:全國 | 上海華線醫(yī)用核子儀器有限公司 聯(lián)系時請告知消息來自3618醫(yī)療器械網(wǎng),您會獲得更多的優(yōu)惠或支持 聯(lián)系人:****** 聯(lián)系電話:****** 訪問量:121835 |
性能特點:
★全彩色大屏幕液晶屏顯示和屏幕觸摸方式操作;
★預置四個固定程序(包裹、溶液、器械、測試)和留有兩個自定義空間,供用戶個
性化設定工作程序;
★采用微電腦模塊化設計的控制系統(tǒng), 水箱和滅菌室雙重PID溫度控制;
★配置微型打印機打印滅菌過程的關(guān)鍵參數(shù);
★雙壓力雙溫度數(shù)字動態(tài)顯示和壓力表顯示;
★屏幕采用人機對話和提示的方法,有效避免錯誤操作的發(fā)生;
★門開啟和鎖閉為電動方法,控制靈活可靠;
★滅菌器為帶蒸汽發(fā)生器和夾套結(jié)構(gòu)的設計;
★滅菌室和夾套分別設有過壓保護裝置;
★夾套和滅菌室分別有超溫報警控制,報警后停止滅菌程序;
★滅菌條件(夾套預熱溫度、鎖門和密封等)不符合,不能進入滅菌程序;
★滅菌器設有安全退出程序,因故中斷滅菌程序,確認退出后,系統(tǒng)自動按照“安全
退出”方法結(jié)束滅菌工作
★滅菌器工作過程發(fā)生缺水現(xiàn)象,能自動切斷加熱電源并實現(xiàn)補水,補水結(jié)束繼續(xù)工
作;
★滅菌工作結(jié)束,溫度和壓力達到開門條件后,警報器和屏幕同時提示;
★一體化水環(huán)真空泵, 噪聲小且真空度可以達到-0.09MPa以下;
★高滅菌溫度可達135℃。
YX0.6WM
Performance and characteristic:
D This product adopts a large full-color LCD screen and touch-ba[x]sed operatingsystem.
Presets four fixed programs(Operation kits, fluid, scalpels, testing) and two customized areas for personalized programs setting.
Adopts a control system of micro-computer modularized design to control dual PID temperature in the water tank and sterilization chamber
Configures micro-printer to print key parameters during the sterilization process.
-Dynamically digital displays dual pressure, dual temperature and pressure gauge
The screen features man-machine interaction and hints, so faulty operations could be effectively avoided.
tbooropongandockng are in the elect c mode to support ex by and re by
The sterilizer features own steam generator and design of jacket structure.
卜Sterilization chamber and jacket have overvoltage protection devices, respectively.
Jacket and sterilization chamber have over-temperature alarm control system, respectively.Sterilization procedures will be terminated once the alarm is on.
卜lf sterilization conditions(jacket preheating temperature, locking door and sealing) are not met, sterilization procedures will not work.
卜Sterilizer has safety exit procedures.If sterilization procedures are interrupted, staff should confirm to exit.Then the system will be automatically inc cordance
with‘safety exit procedures’to terminate the sterilization.
-lf sterilization chamber happens to be water shortage during the working process, heating powersupply will be automatically cutoff for water replenishment.After
finishing water replenishment, working process will continue.
卜After sterilization process finishes, alarm and screen will be prompt simultaneously if temperature and pressure meet the condition of door opening.
Integrated water ring vacuum pump with lownoise and vacuum pressure reaches less than 0.09MPa
-Maximum sterilization temperature up to 135℃
更多 醫(yī)用臥式方形脈動真空壓力蒸汽滅菌器 價格、說明、廠家,請關(guān)注3618醫(yī)療器械網(wǎng)* 溫馨提示:請仔細閱讀產(chǎn)品說明書或在醫(yī)務、專業(yè)人員指導下購買和使用,禁忌內(nèi)容或者注意事項詳見說明書。